TPD 5/3.5 mm 1-26 -way Tr, TIA598
- For installation in existing ducts
- 1, 2, 4, 7, 12, 19, 24 or 26 over-sheathed ducts
- 5/3.5 mm microducts
- Low friction inner surface for maximum installation lengths
- Excellent environmental properties
- Integrated tracer wire under sheath
Application
The tight protected duct assemblies consist of a number of microducts with an inner low friction, antistatic surface that enables installation of air blown fiber. The duct assemblies are bundled with a single HDPE sheath depending on configuration. The design makes the duct assemblies especially suitable for installation into narrow existing ducts (pipes) or pipes occupied with cables or other obstacles. The round structure enables easy splicing and sealing at joints and branch locations. The microducts are optimized for best performance in combination with the Hexatronic Stingray Air Blown Fibers and Hexatronic Raptor Nano Cables.
The integrated tracer wire saves time and installation cost since an additional wire for tracing is not required.
Design
The duct assemblies are available in several versions with 1 to 26 microducts.
Each microduct has an outer/inner diameter of 5/3.5 mm. These are suitable for installation of air blown fibers. The center duct of 24 and 26-way assemblies is 10/8 resp. 12/10 mm and can be used for blowing in a micro cable.
Product Information
Microducts and outer sheath: HDPE
Tracer Wire
Single ducts: 24 AWG (0.2 mm²)
Microduct assemblies: 18 AWG (0.8 mm²)
Material: Isolated, stranded copper
Technical Information
Color CodeTIA598Temperature, Operation [°C]-40 to +60Temperature, Storage [°C]-40 to +60Temperature, Installation [°C]-20 to +50Conformance
Abrasion: IEC 60794-1-2-E2B(1)
Kink: IEC 60794-1-2-E10, 20 x outer diameter
Impact: IEC 60794-1-2-E4
Crush: IEC 60794-1-2-E3
Tensile: IEC 60794-1-2-E
Bend: IEC 60794-1-2-E11A
Torsion: IEC 60794-1-2-E
Flexibility: IEC 60794-1-2-E8
Inner Clearance: IEC 60794-5-20, IEC 60794-5-10, Ann. D
MarkingDuct assemblies have markings showing the tube length. The individual microducts are numbered and also identified by their color and position in the bundle according to the TIA598 standard.
The assemblies are available in various sheath colors for easy identification.
- Choosing a selection results in a full page refresh.